Engine Mechanical - 1.6L (LDE or LLU) and 1.8L (2H0)
🢒 Intake Manifold Installation
Intake Manifold Installation 2H0
Clean the sealing surfaces.
Insert 4 NEW gaskets.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the intake manifold and the 7 bolts (1) and tighten to
20N·m (15 lb ft)
.
Install the intake manifold support (1) and the 2 intake manifold support bolts (2, 3) and tighten to
8N·m (71 lb in)
.
Intake Manifold Installation LDE
Clean the sealing surfaces.
Insert the NEW gasket.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the intake manifold (2) and the 7 intake manifold bolts (1) and tighten to
20 N·m (15 lb ft)
.
Install the intake manifold support (1) and the 2 bolts (2, 3) and tighten to
8 N·m (71 lb in)
.
Intake Manifold Installation LLU
Install the intake manifold sealing (4).
Install the intake manifold (3).
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the 3 intake manifold nuts (2) and tighten to
20 N·m (15 lb ft)
.
Install the 5 intake manifold bolts (1) and tighten to