Cleaning Procedure
- Clean the oil filter adapter components with non-corrosive solvent.
Warning: Wear safety glasses when using compressed air, as flying dirt particles may cause eye injury.
- Dry the oil filter adapter components with compressed air.
Inspection Procedure
Note: The internal parts of the oil filter adapter housing are not serviced separately. If wear or damage is noted, replace the entire oil filter adapter assembly.
- Inspect the oil filter adapter housing for cracks, casting imperfections or damage (5).
- Inspect the threads for the oil pressure sender (4) or bracket (2) for damage.
- Inspect the oil filter sealing surface for damage.
- Inspect the threads for the oil filter fitting (1) for damage.
- Inspect the mounting holes (3) for damage.
- Inspect the oil filter adapter housing gasket sealing surface (1) for damage.
- Inspect the oil filter adapter housing passages (2) for damage or blockage.
- Repair or replace the oil filter adapter housing as necessary.