For equivalent regional tools, refer to
Special Tools.
Ensure that the secondary timing chain tensioner bank 2 (2) is being installed.
Using the
EN-49416 reset tool
, reset the secondary timing chain tensioner plunger.
Install the plunger into the secondary timing chain tensioner body.
Compress the plunger into the body and lock the secondary timing chain tensioner by inserting the
EN 46112 pin
into the access hole in the side of the secondary
timing chain tensioner body.
Slowly release pressure on the secondary timing chain tensioner. The secondary timing chain tensioner should remain compressed.
Verify the proper placement of the secondary timing chain tensioner gasket tab (1).