• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Blower Motor Control Module B+ | B0193 06 | B0193 06 | -- | -- |
Blower Motor B+ | 1 | 1 | -- | -- |
Blower Motor Control Module Control | B0193 06 | B0193 06 | B0193 01 | -- |
Blower Motor Control | 2 | 1 | 1 | -- |
Blower Motor Control Module Ground | -- | B0193 06 | -- | -- |
|
The blower motor control module is an interface between the HVAC control module and the blower motor. The blower motor speed control from the HVAC control module, battery positive and ground circuits enable the blower motor control module to operate. The HVAC control module provides a pulse width modulation (PWM) signal to the blower motor control module in order to command the blower motor speed. The blower motor control module transfers the PWM signal into a corresponding blower motor voltage. The voltage amounts to between 2-13 V and changes linear to the reading of the PWM signal.
Check the following mechanical fault sources:
• | Air distribution box |
• | Air distribution hoses / air distribution ducts |
Manual HVAC Description and Operation
Control Module References for scan tool information
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If greater than the specified value, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the K8 Blower Motor Control Module. |
⇒ | If the test lamp illuminates brightly continuously, test the control circuit for a short to ground. If the circuit tests normal, replace the K8 Blower Motor Control Module and verify that the test lamp does not always illuminate brightly. If the test lamp always illuminates brightly, replace the K33 HVAC Control Module. |
⇒ | If the test lamp does not illuminate, test the control circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K8 Blower Motor Control Module and verify that the test lamp illuminates. If the test lamp does not illuminate, replace the K33 HVAC Control Module. |
⇒ | If the test lamp intensity does not vary, replace the K8 Blower Motor Control Module and verify that the intensity varies. If the test lamp intensity does not vary, replace the K33 HVAC Control Module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.