• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Blower Motor Control Module B+ | B0193 06 | B0193 06 | -- | -- |
Blower Motor Control Module Control | B0193 06 | B0193 06 | B0193 01 | -- |
Blower Motor Control Module Ground | -- | B0193 06 | -- | -- |
The blower motor control module is an interface between the HVAC control module and the blower motor. The blower motor speed control from the HVAC control module, battery positive and ground circuits enable the blower motor control module to operate. The HVAC control module provides a pulse width modulation (PWM) signal to the blower motor control module in order to command the blower motor speed. The blower motor control module transfers the PWM signal into a corresponding blower motor voltage. The voltage resides between 2-13 V and changes linear to the height of the PWM signal.
• | Ignition ON. |
• | The HVAC control module is ON. |
The voltage at the HVAC control module output to the blower motor control module is always high.
The voltage at the HVAC control module output to the blower motor control module is always low or floating.
The blower motor is inoperative.
The condition for setting the DTC is no longer present.
Automatic HVAC Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
⇒ | If the test lamp does not illuminate, test the ground circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the control circuit for a short to voltage. |
⇒ | If less than the specified range, test the control circuit for a short to ground. |
⇒ | If greater than the specified value, test the control circuit for an open/high resistance. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
Perform the Diagnostic Repair Verification