• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Stepper Motors 12 V Reference | B023A 02, B0223 06, B0233 06, B0408 06 | B0223 06, B0233 06, B0408 06 | -- | -- |
Recirculation Actuator Control 1 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 2 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 3 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 4 | B0223 06 | B0223 06 | B0223 01 | 1 |
Air Temperature Actuator - Left Control 1 | B0408 06 | B0408 06 | B0408 01 | 2 |
Air Temperature Actuator - Left Control 2 | B0408 06 | B0408 06 | B0408 01 | 2 |
Air Temperature Actuator - Left Control 3 | B0408 06 | B0408 06 | B0408 01 | 2 |
Air Temperature Actuator - Left Control 4 | B0408 06 | B0408 06 | B0408 01 | 2 |
Mode Actuator Control 1 | B0233 06 | B0233 06 | B0233 01 | 3 |
Mode Actuator Control 2 | B0233 06 | B0233 06 | B0233 01 | 3 |
Mode Actuator Control 3 | B0233 06 | B0233 06 | B0233 01 | 3 |
Mode Actuator Control 4 | B0233 06 | B0233 06 | B0233 01 | 3 |
|
The stepper motors supply output is shorted to ground.
At least one control output (of four possible outputs) of the appropriate stepper motor is shorted to voltage when motor starts moving. Faults are not detected when motor is already running or target position is already reached.
At least one control output (of four possible outputs) of the appropriate stepper motor is shorted to ground or open when motor starts moving. Faults are not detected when motor is already running or target position is already reached.
• | The affected output will be switched off for hardware protection. |
• | All stepper motors are deactivated. |
• | The affected output will be switched off for hardware protection. |
• | The affected stepper motor is deactivated. |
The condition for setting the DTC is no longer present.
Manual HVAC Description and Operation
⇒ | If DTC is present, refer to Actuator Power Supply Malfunction. |
⇒ | If DTC is present, refer to Recirculation Actuator Malfunction. |
⇒ | If DTC is present, refer to Mode Actuator Malfunction. |
⇒ | If DTC is present, refer to Air Temperature Actuator - Left Malfunction. |
⇒ | If less than the specified value, test the reference voltage circuit for a short to ground. |
• | Terminal 16 (X3) |
• | Terminal 17 (X3) |
• | Terminal 18 (X3) |
• | Terminal 19 (X3) |
⇒ | If greater than the specified value, test the control circuit for a short to voltage. |
• | Terminal 16 (X3) |
• | Terminal 17 (X3) |
• | Terminal 18 (X3) |
• | Terminal 19 (X3) |
⇒ | If less than the specified value, test the control circuit for a short to ground. |
• | M46 Recirculation Actuator terminal 1 and terminal 16 (X3) at the K33 HVAC Control Module harness connector |
• | M46 Recirculation Actuator terminal 2 and terminal 15 (X3) at the K33 HVAC Control Module harness connector |
• | M46 Recirculation Actuator terminal 3 and terminal 17 (X3) at the K33 HVAC Control Module harness connector |
• | M46 Recirculation Actuator terminal 4 and terminal 18 (X3) at the K33 HVAC Control Module harness connector |
• | M46 Recirculation Actuator terminal 6 and terminal 19 (X3) at the K33 HVAC Control Module harness connector |
⇒ | If greater than the specified value, test the control circuit for an open/high resistance. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
• | Terminal 2 (X3) |
• | Terminal 3 (X3) |
• | Terminal 4 (X3) |
• | Terminal 5 (X3) |
⇒ | If greater than the specified value, test the control circuit for a short to voltage. |
• | Terminal 2 (X3) |
• | Terminal 3 (X3) |
• | Terminal 4 (X3) |
• | Terminal 5 (X3) |
⇒ | If less than the specified value, test the control circuit for a short to ground. |
• | M37 Mode Actuator terminal 1 and terminal 2 (X3) at the K33 HVAC Control Module harness connector |
• | M37 Mode Actuator terminal 2 and terminal 15 (X3) at the K33 HVAC Control Module harness connector |
• | M37 Mode Actuator terminal 3 and terminal 3 (X3) at the K33 HVAC Control Module harness connector |
• | M37 Mode Actuator terminal 4 and terminal 4 (X3) at the K33 HVAC Control Module harness connector |
• | M37 Mode Actuator terminal 6 and terminal 5 (X3) at the K33 HVAC Control Module harness connector |
⇒ | If greater than the specified value, test the control circuit for an open/high resistance. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
• | Terminal 11 (X3) |
• | Terminal 12 (X3) |
• | Terminal 13 (X3) |
• | Terminal 14 (X3) |
⇒ | If greater than the specified value, test the control circuit for a short to voltage. |
• | Terminal 11 (X3) |
• | Terminal 12 (X3) |
• | Terminal 13 (X3) |
• | Terminal 14 (X3) |
⇒ | If less than the specified value, test the control circuit for a short to ground. |
• | M6L Air Temperature Actuator - Left terminal 1 and terminal 11 (X3) at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Actuator - Left terminal 2 and terminal 15 (X3) at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Actuator - Left terminal 3 and terminal 12 (X3) at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Actuator - Left terminal 4 and terminal 13 (X3) at the K33 HVAC Control Module harness connector |
• | M6L Air Temperature Actuator - Left terminal 6 and terminal 14 (X3) at the K33 HVAC Control Module harness connector |
⇒ | If greater than the specified value, test the control circuit for an open/high resistance. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
Perform the Diagnostic Repair Verification