• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Windshield Temperature and Inside Moisture Sensor 5 V Reference | B1395 03 | B1395 03 | B1395 07 | -- |
Humidity Signal | B048C 02 | B048C 05 | B048C 05 | -- |
Humidity Temperature Signal | B048F 02 | B048F 05 | B048F 05 | -- |
Windshield Temperature Signal | B018A 02 | B018A 05 | B018A 05 | -- |
Windshield Temperature and Inside Moisture Sensor Ground | -- | B018A 05, B048C 05, B048F 05, B1395 03 | -- | -- |
The windshield temperature and inside moisture sensor includes the relative humidity sensor, windshield temperature sensor and humidity sensing element temperature sensor.
This sensor assembly provides information about:
• | Relative humidity level at windshield inside |
• | Temperature of the windshield inside |
• | Temperature of the humidity sensor element |
The relative humidity sensor measures the relative humidity of the compartment side of the windshield. It also detects the temperature of the windshield surface on the compartment side. Both values are used as control inputs for the HVAC control module application to calculate the fog risk on windshield compartment side and ability to reduce fuel consumption by decreasing A/C compressor power to a minimum without causing any fog. The sensor will also enable partial recirculation mode in order to improve heat-up performance of the passenger compartment under cold ambient temperature conditions without the risk of mist build-up on the windshield. The humidity sensor element temperature sensor supplies the temperature of the humidity sensor element. It is only needed if the thermal contact between the humidity sensing element and the inside windshield surface is not sufficient.
• | Ignition ON. |
• | The HVAC control module is ON. |
The HVAC control module detects the sensor signal out of range. The signal voltage is less than 0.1 V for more than 50 ms.
The HVAC control module detects the sensor signal out of range. The signal voltage is greater than 4.9 V for more than 50 ms.
• | The system will use the last valid values as default. |
• | If no value is read at the time of fault, the HVAC control module uses 60% for humidity. |
The condition for setting the DTC is no longer present.
Automatic HVAC Description and Operation
Control Module References for scan tool information
⇒ | If DTC is present, refer to Windshield Temperature And Inside Moisture Sensor Power Supply Malfunction. |
⇒ | If DTC is present, refer to Humidity Sensor Humidity Circuit Malfunction. |
⇒ | If DTC is present, refer to Humidity Sensor Temperature Circuit Malfunction. |
⇒ | If DTC is present, refer to Windshield Temperature Sensor Circuit Malfunction. |
⇒ | If not within the specified range, replace the B160 Windshield Temperature and Inside Moisture Sensor. |
⇒ | If not within the specified range, replace the B160 Windshield Temperature and Inside Moisture Sensor. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or open/high resistance. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
⇒ | If less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
⇒ | If less than the specified range, test the signal circuit terminal for a short to ground or open/high resistance. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If greater than the specified range, test the signal circuit terminal for a short to battery. If the circuit tests normal, replace the K33 HVAC Control Module. |
⇒ | If the DTC resets, replace the K33 HVAC Control Module. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, setup, and programming |