• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Stepper Motors 12 V Reference | B023A 02, B0223 06, B0233 06, B0408 06 | B0223 06, B0233 06, B0408 06 | -- | -- |
Recirculation Actuator Control 1 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 2 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 3 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 4 | B0223 06 | B0223 06 | B0223 01 | 1 |
1. Air Recirculation Malfunction |
The desired position of the recirculation flap can be set with the recirculation switch at the HVAC control. The selected value is sent to the HVAC control module via the LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor moves the recirculation flap into the selected position.
Check the following mechanical fault sources:
• | Air distribution box |
• | Air distribution hoses / air distribution ducts |
Automatic HVAC Description and Operation
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If not the specified value, replace the A26 HVAC Control. |
Perform the Diagnostic Repair Verification
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Stepper Motors 12 V Reference | B023A 02, B0223 06, B022A 06, B0233 06, B0408 06, B0418 06 | B0223 06, B022A 06, B0233 06, B0408 06, B0418 06 | -- | -- |
Recirculation Actuator Control 1 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 2 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 3 | B0223 06 | B0223 06 | B0223 01 | 1 |
Recirculation Actuator Control 4 | B0223 06 | B0223 06 | B0223 01 | 1 |
Air Inlet Actuator Control 1 | B022A 06 | B022A 06 | B022A 01 | 1 |
Air Inlet Actuator Control 2 | B022A 06 | B022A 06 | B022A 01 | 1 |
Air Inlet Actuator Control 2 | B022A 06 | B022A 06 | B022A 01 | 1 |
Air Inlet Actuator Control 2 | B022A 06 | B022A 06 | B022A 01 | 1 |
1. Air Recirculation Malfunction |
The desired position of the recirculation flap can be set with the recirculation switch at the HVAC control. The selected value is sent to the HVAC control module via the LIN-Bus. Two stepper motors are used for the recirculation and fresh air control. The first stepper motor moves the air inlet flap, the second stepper motor moves the recirculation flap. In the recirculation mode the air inlet flap closes and the recirculation flap opens in order to circulate the air within the vehicle. In fresh air mode the air inlet flap opens and the recirculation flap is closed again in order to route outside air into the vehicle. The HVAC control module supplies a 12 V reference voltage to both stepper motors and energizes the appropriate 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the recirculation flap and fresh air flap into the selected position.
Check the following mechanical fault sources:
• | Air distribution box |
• | Air distribution hoses / air distribution ducts |
Automatic HVAC Description and Operation
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If not the specified value, replace the A26 HVAC Control. |
⇒ | If the M46 Recirculation Actuator cannot be put into all positions, replace the M46 Recirculation Actuator and verify the M46 Recirculation Actuator can be put into all positions. If the M46 Recirculation Actuator cannot be put into all positions, replace the K33 HVAC Control Module. |
Perform the Diagnostic Repair Verification