• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
B+ Terminal D12 X3 | B1325 03, B1517 5A* | B1325 03, B1517 5A* | -- | -- |
B+ Terminal 11 X1 | B1517 5A | B1517 5A | -- | -- |
Ground | -- | B1517 5A | -- | -- |
*The scan tool will not power up from the DLC if the B+ circuit terminal D12 X3 is open or shorted to ground. |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Ignition ON, Engine OFF. Parameter Normal Value: 12.60 V | |||
B+ Terminal D12 X3 | 0.00 V* | 0.00 V* | -- |
*The scan tool will not power up from the DLC if the B+ circuit terminal D12 X3 is open or shorted to ground. |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Ignition ON, Engine OFF. Parameter Normal Value: 12.600 Volts | |||
B+ Terminal 11 X1 | 0.000 V | 0.000 V | -- |
Ground Terminal 9 X1 | -- | 0.000 V | -- |
The body control module (BCM) has 2 circuits for monitoring vehicle system voltage. The circuits are supplied by the IBCM 1 fuse and the BATT SENSE fuse. The BCM monitors the system voltage on the 2 B+ circuits to ensure that the voltage stays within the normal range. Damage to components, and incorrect data may occur when the voltage is out of range.
The BCM is awake.
The voltage of the 2 BCM battery sense circuits differ by 1 V for 10 seconds.
Regulated voltage control (RVC) is disabled.
• | The DTC will pass when the malfunction is no longer present for 10 seconds. |
• | A history DTC will clear after 50 consecutive ignition cycles have occurred without a malfunction. |
A high or low voltage DTC in multiple modules indicates a concern in the charging system.
Starting and Charging Schematics
Charging System Description and Operation
Control Module References for scan tool information
⇒ | If not within the specified range, refer to Charging System Test. |
• | The Ign Sensor fuse |
• | The Interior Lights fuse |
• | The Door Lock fuse |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
• | Terminal 9 X1 |
• | Terminal 12 X1 |
• | Terminal 13 X2 |
• | Terminal E12 X4 |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
• | Terminal 11 X1 |
• | Terminal D12 X3 |
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References - for BCM replacement, setup, and programming.