When you first turn the ignition switch to the RUN position, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within itself. Upon passing these tests IGNITION, 23 VLR and the deployment loop voltages are measured to make sure they are within their respective normal voltage ranges. The SDM monitors the voltages at Driver Side Low terminal 10 and Passenger Side Low terminal 14 to detect shorts to ground in the side air bag deployment loops. The service wait time is 10 minutes. Refer to ENABLE/DISABLE procedures.
• | The driver side air bag deployment loop is not open. |
• | The driver side air bag deployment loop is not shorted to voltage. |
• | The voltage at Driver Side Low terminal 10 is less than 1.25 volts for 500 milliseconds. |
The following tests check for this DTC. These tests occur when IGNITION is within the normal operating voltage range.
• | POWER-ON When the malfunction is detected in this test, the RESISTANCE MEASUREMENT test will not be performed. |
• | CONTINUOUS MONITORING |
• | The SDM sets a DTC B1013. |
• | The SDM turns ON the AIR BAG warning lamp. |
• | Current DTC |
The voltage at Driver Side Low terminal 10 is greater than 2.5 volts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command. |
- | Once 250 malfunction free ignition cycles have occurred. |
A short to ground in the inflatable restraint driver seat module circuit can cause an intermittent condition. Inspect CKT 2137 and CKT 2138 carefully for cutting or chafing. Wiring pigtail damage requires replacement of the inflatable restraint driver seat module. The diagnostic table directs the technician to note the entry value of LH SIDE AIR BAG SENSELO. Comparing the value of LH SIDE AIR BAG SENSELO can be helpful in determining if an intermittent condition exists.
When measurements are requested in this table, use J 39200 Digital Multimeter with the correct terminal adapter from J 35616 Connector Test Adapter Kit. When a check for proper connection is requested, refer to Intermittents and Poor Connections . When a wire, connector or terminal repair is requested, use J-38125 Terminal Repair Kit and refer to Wiring Repair .
The numbers below refer to the step numbers on the diagnostic table:
This step isolates the malfunction to one side of the inflatable restraint front side impact module (LH) yellow 2-way connector.
This step checks to see if there is a short to ground in CKT 2138.
This step determines if there is a short to ground in CKT 2137 or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
2 |
Is the LH SIDE AIR BAG SENSELO less than the specified value? | 1.25 V | Refer to Diagnostic Aids | |
Is LH SIDE AIR BAG SENSELO less than the specified value? | 1.25 V | |||
4 |
Is the repair complete? | -- | -- | |
Is the measured resistance less than the specified value? | OL | |||
6 |
Is the repair complete? | -- | -- | |
Use the J 39200 to measure the resistance between terminal B of the inflatable restraint front side impact module (LH) yellow 2-way wiring harness connector and a known good ground. Is the measured resistance less than the specified value? | OL | |||
8 |
Is the repair complete? | -- | -- | |
9 | Reconnect all the SIR system components, making sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- | |
10 | Use the scan tool to clear all current and history SIR DTCs. Have all current and history SIR DTCs been cleared? | -- | -- |