Step | Action | Value(s) | Yes | No | ||||
---|---|---|---|---|---|---|---|---|
1 | Inspect the T/SIG fuse. Is the fuse open? | -- | Go to Step 2 | Go to Step 3 | ||||
2 | Repair a short to ground in one of the following circuits:
Is the repair complete? | -- | -- | |||||
3 |
Did the test lamp light? | -- | Go to Step 5 | Go to Step 4 | ||||
4 | Repair the following conditions in CKT 539:
Is the repair complete? | -- | -- | |||||
5 | Use a test light in order to backprobe between connector C201 terminal E1 and ground. Does the test light illuminate? | -- | Go to Step 7 | Go to Step 6 | ||||
6 |
Is the repair complete? | -- | -- | |||||
7 | Use a test light to backprobe the hazard lamp/turn signal flasher between connector terminal A1 and connector terminal B2. For EXPORT vehicles backprobe the hazard lamp/turn signal flasher between connector terminal 2 and connector terminal 5. Does the test light illuminate? | -- | Go to Step 9 | Go to Step 8 | ||||
8 | Repair the following conditions, as needed:
Has the repair been made? | -- | -- | |||||
9 |
Is the test light flashing? | -- | Go to Step 11 | Go to Step 10 | ||||
10 | Replace the turn signal/hazard lamp flasher. Has the repair been made? | -- | -- | |||||
11 |
Is the test light flashing? | -- | Go to Step 6 | Go to Step 12 | ||||
12 | Repair the faulty connection or the open in CKT 16. Has the repair been made? | -- | -- |