When you first turn the ignition switch to the RUN position, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within itself. Upon passing these tests IGNITION, 23 VLR and the deployment loop voltages are measured to make sure they are within their respective normal voltage ranges. The SDM monitors the voltages at Driver Frontal Low terminal 2 and Passenger Frontal Low terminal 3 to detect shorts to B+ in the frontal air bag deployment loop circuits.
• | The voltage at Driver Frontal Low terminal 2 is less than 3.5 volts. |
• | The voltage at Passenger Frontal Low terminal 3 is more than 4.5 volts for 500 milliseconds. |
The CONTINUOUS MONITORING test checks for this DTC. This test occurs when IGNITION is within the normal operating voltage range.
• | The SDM sets a DTC B1019. |
• | The SDM turns ON the AIR BAG warning lamp. |
• | Current DTC-The voltage at Passenger Frontal Low terminal 3 is less than 3.5 volts for 500 milliseconds. |
• | History DTC |
- | You issue a scan tool CLEAR CODES command. |
- | Once 250 malfunction free ignition cycles have occurred. |
A short to B+ in the inflatable restraint IP module circuit can cause an intermittent condition. Inspect CKT 1403 and CKT 1404 carefully for cutting or chafing. Wiring pigtail damage requires replacement of the inflatable restraint IP module. The diagnostic table directs the technician to note the entry value of PASSENGER SENSELO. Comparing the value of PASSENGER SENSELO can be helpful in determining if an intermittent condition exists.
When measurements are requested in this table, use J 39200 Digital Multimeter with the correct terminal adapter from J 35616 Connector Test Adapter Kit. When a check for proper connection is requested, refer to Intermittents and Poor Connections . When a wire, connector or terminal repair is requested, use J-38125 Terminal Repair Kit and refer to Wiring Repair .
The numbers below refer to the step numbers on the diagnostic table:
This step isolates the malfunction to one side of the inflatable restraint IP module yellow 2-way connector.
This step checks to see if there is a short to B+ in CKT 1403.
This step determines if there is a short to B+ in CKT 1404 or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the SIR Diagnostic System Check performed? | -- | ||
2 |
Has the PASS. FRONTAL SENSELO been read and recorded on the repair order? | -- | -- | |
Is PASS. FRONTAL SENSELO more than the specified value? | 4.5 V | |||
4 |
Is the repair complete? | -- | -- | |
Is the measured voltage less than the specified value? | 1.0 V | |||
6 |
Is the repair complete? | -- | -- | |
Use the J 39200 Digital Multimeter (DMM) to measure the voltage between terminal A of the inflatable restraint IP module yellow 2-way wiring harness connector and a known good ground. Is the measured voltage less than the specified value? | 1.0 V | |||
8 |
Is the repair complete? | -- | -- | |
9 | Reconnect all the SIR system components, making sure all the components are properly mounted. Have all the SIR components been reconnected and properly mounted? | -- | -- | |
10 | Use the scan tool to clear all current and history SIR DTCs. Have all current and history SIR DTCs been cleared? | -- | -- |