Instrument Panel Inflatable Restraint Module Replacement Aztek
Removal Procedure
Caution: Refer to SIR Caution in the Preface section.
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
- Disable the SIR system. Refer to
Disabling the SIR System
.
- Remove the instrument panel (I/P) compartment. Refer to
Instrument Panel Compartment Replacement
.
- Disconnect the inflator module connector.
- Remove the I/P nuts from the inflator restraint module.
- Remove the inflatable restraint module (1) from the I/P.
- Fully deploy the module before disposal. If the module was replaced under
warranty, fully deploy and dispose of the module after the required retention period.
Refer to
Inflator Module Handling and Scrapping
.
Installation Procedure
- Install the inflatable restraint module (1)
to the I/P.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the I/P nuts to the inflatable restraint module.
Tighten
Tighten the nuts to 10 N·m (89 lb in).
- Connect the inflatable restraint module connector.
- Install the I/P compartment. Refer to
Instrument Panel Compartment Replacement
.
- Enable the SIR system. Refer to
Enabling the SIR System
.