Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Instrument Cluster Schematics | |||
1 | Did you perform the IPC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the DIC display OC? | Go to Step 4 | Go to Step 3 |
3 | Test the signal circuit of the ambient air temperature sensor for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 5 |
4 | Inspect for poor connections at the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 7 | Go to Step 6 |
5 |
Important: Perform the compass calibration and variance procedure on the replacement IPC. Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | Go to Step 7 | -- |
6 | Replace the ambient air temperature sensor. Refer to Ambient Temperature Sensor Replacement . Did you complete the replacement? | Go to Step 7 | -- |
7 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |