Tools Required
J 39400-A Halogen
Leak Detector
Removal Procedure
- Recover the refrigerant from the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Disconnect the A/C refrigerant
hose.
• | For compression style fittings use a back up wrench on the fitting
(2) and loosen the fitting nut (1). |
• | For banjo style fittings remove the bolt retaining the banjo type
fitting. |
Important: Cap or tape the open A/C refrigerant hose and the A/C refrigerant component
immediately.
- Disconnect the A/C hose from the A/C component.
- Cap or tape the A/C hose and the A/C component to prevent system
contamination, discard the O-ring seals.
Installation Procedure
- Remove the cap or tape from the A/C hose and the A/C component.
- Using a lint-free clean, dry cloth, carefully clean the sealing
surfaces of the A/C refrigerant hose and the A/C refrigerant component.
- Lightly coat the new O-ring seal with mineral base 525 viscosity
refrigerant oil.
Important: DO NOT allow any of the mineral base 525 viscosity refrigerant
oil on the new O-ring seal to enter the refrigerant system.
- Carefully slide the new O-ring seal onto the A/C refrigerant hose.
- The O-ring seal must be
fully seated.
- Connect the A/C refrigerant
hose.
• | For compression style fittings use a back up wrench on the fitting
(2) and tighten the fitting nut (1) to specification. |
• | For banjo style fittings install the bolt retaining the banjo
type fitting and tighten to specification. |
- Evacuate and recharge the A/C system. Refer to
Refrigerant Recovery and Recharging
.
- Leak test the fittings of the component using J 39400-A
.