HVAC Control Module Replacement Buick
Removal Procedure
- Remove the IP cluster trim plate bezel . Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gages and Console.
- Remove the HVAC control
module retaining screws.
- Pull the HVAC control
module straight out from the IP.
- Disconnect the HVAC control module electrical connector.
Installation Procedure
- Connect the HVAC control module electrical connector.
- Install the HVAC control
module into the IP opening.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the HVAC control module retaining screws.
Tighten
Tighten the screws to 2.5 N·m (22 lb in).
- Install the IP cluster trim plate bezel . Refer to
Instrument Panel Cluster Trim Plate Bezel Replacement
in Instrument
Panel, Gages, and Console.
HVAC Control Module Replacement Pontiac
Removal Procedure
- Remove the instrument panel accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument
Panel, Gages and Console.
- Remove the HVAC control
module retaining screws.
- Pull the HVAC control
module straight out from the instrument panel.
- Disconnect the HVAC control module electrical connectors.
Installation Procedure
- Connect the HVAC control module electrical connectors.
- Push the HVAC control
module into instrument panel opening.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the HVAC
control module retaining screws.
Tighten
Tighten the screws to 2.5 N·m (22 lb in).
- Install the instrument panel accessory trim plate. Refer to
Instrument Panel Accessory Trim Plate Replacement
in Instrument
Panel, Gages, and Console.