The numbers below refer to the step numbers on the diagnostic table.
This step tests for a high resistance in the signal circuit and the ground circuit of the ambient air temperature sensor.
DTCs may be set in the IPC when you perform this diagnostic table.
Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Schematic Reference: Instrument Cluster Schematics | ||||
1 | Did you perform the Instrument Panel Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the temperature displayed on the DIC match the current room temperature within 3°F (2°C)? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
Important: Verify the J 33431-C resistance settings with a DMM. Does the DIC display the specified value? | 54°C (130°F) | Go to Step 6 | Go to Step 4 | |
4 | Test the ambient air temperature sensor signal circuit for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 5 |
5 | Test the ground circuit of the ambient air temperature sensor for a high resistance. Refer to Circuit Testing and to Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 7 |
6 | Inspect for poor connections at the harness connector of the ambient air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 8 |
7 | Inspect for poor connections at the harness connector of the IPC. Refer to Testing for Intermittent Conditions and Poor Connections and to Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 10 | Go to Step 9 |
8 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Gage Sensor Replacement . Did you complete the replacement? | -- | Go to Step 10 | -- |
9 |
Important: Perform the compass calibration and variance procedure on the replacement IPC. Replace the IPC. Refer to Instrument Cluster Replacement . Did you complete the replacement? | -- | Go to Step 10 | -- |
Did you correct the condition? | -- | System OK | Go to Step 2 |