Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Exterior Lights Schematics | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do the backup lamps turn on in REVERSE and turn off in PARK? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Disconnect the Park Neutral Position (PNP) switch. Do the backup lamps turn OFF? | Go to Step 5 | Go to Step 4 |
4 | Repair the short in the backup lamps supply voltage circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 6 | -- |
5 | Replace the PNP switch. Refer to Park/Neutral Position Switch Replacement in Automatic Transaxle-4T65-E. Did you complete the replacement? | Go to Step 6 | -- |
6 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |