Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems. | |||
1 | Did you perform the Lighting System Diagnostic System Check? | Go to Step 2 | |
2 |
Do both reading lamps illuminate? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Repair the high resistance or an open in the inoperative roof rail reading lamp courtesy lamps supply voltage supply or ground circuit. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 4 | -- |
4 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |