Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |||||||
2 |
Does the boost gauge remain on? | -- | Go to Step 4 | Go to Step 3 | ||||||
3 | Replace the boost/manifold absolute pressure (MAP) sensor. Refer to the appropriate procedure: Is the repair complete? | -- | -- | |||||||
4 | Inspect CKT 891 (BLK) for a short to voltage. Is the wire OK? | -- | Go to Step 6 | Go to Step 5 | ||||||
5 | Repair the short to voltage on CKT 891 (BLK). Did you complete the repair? | -- | -- | |||||||
6 | Inspect connector C101 terminal F7 and connect C200 terminal A9 for proper terminal contact. is the terminal contact OK? | -- | Go to Step 8 | Go to Step 7 | ||||||
7 | Repair the poor terminal contact. Did you complete the repair? | -- | -- | |||||||
8 | Replace the instrument cluster. Refer to one of the following procedures: