Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||||
2 |
Is the voltage within the specified value? | 5 V | Go to Step 3 | Go to Step 4 | ||||||
3 | Measure the voltage from the boost/MAP sensor connector terminal C to terminal A. Is the voltage within the specified value? | 5 V | Go to Step 7 | Go to Step 8 | ||||||
4 |
Did you find a wiring or connection condition? | -- | Go to Step 5 | Go to Step 6 | ||||||
5 | Repair the wiring or poor terminal connections. Is the repair complete? | -- | Go to Step 6 | -- | ||||||
6 | Replace the instrument cluster. Refer to one of the following procedures:
Is the replacement complete? | -- | System OK | |||||||
7 | Connect a fused jumper from boost/MAP sensor connector terminal C to terminal B. Does the boost gauge meet the specified value? | +10 | Go to Step 10 | Go to Step 11 | ||||||
8 |
Did you find a wiring or connection condition? | -- | Go to Step 9 | |||||||
9 | Repair the wiring or connection. Is the repair complete? | -- | -- | |||||||
10 | Inspect the boost/MAP sensor connector for proper terminal contact. Is the terminal contact OK? | -- | Go to Step 12 | Go to Step 11 | ||||||
11 |
Did you find a wiring or connection condition? | -- | Go to Step 13 | Go to Step 14 | ||||||
12 | Replace the boost/MAP sensor. Refer to the appropriate procedure: Is the repair complete? | -- | -- | |||||||
13 | Repair the wiring or connection condition. Is the repair complete? | -- | Go to Step 14 | -- | ||||||
14 | Replace the instrument cluster (IPC). Refer to one of the following procedures:
Is the repair complete? | -- | -- |