Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |
2 |
Does the low washer fluid indicator illuminate? | -- | Go to Step 4 | Go to Step 3 |
3 |
Does the resistance equal the specified value? | 0 ohms | Go to Step 6 | Go to Step 5 |
4 | Test the washer fluid level switch connector for proper terminal contact at terminals A and B. Is the terminal contact OK? | -- | Go to Step 8 | Go to Step 7 |
5 | Test CKT 99 (BLK/WHT) for an open or a short to the battery. Is the wiring OK? | -- | Go to Step 11 | Go to Step 10 |
6 | Test the instrument cluster connector for proper terminal contact at terminal A11 (Pontiac w/UB3) or D11 (Oldsmobile w/ UH8). Is the terminal contact OK? | -- | Go to Step 9 | Go to Step 7 |
7 | Repair the poor terminal contact. Is the repair complete? | -- | -- | |
8 | Replace the washer fluid level switch. Is the replacement complete? | -- | -- | |
9 | Replace the instrument cluster. Is the replacement complete? | -- | -- | |
10 | Repair the open or short to voltage on CKT 99 (BLK/WHT). Is the repair complete? | -- | -- | |
11 | Test CKT 1150 (BLK) for an open. Is the wiring OK? | -- | Go to Step 7 | Go to Step 12 |
12 | Repair the open on CKT 1150 (BLK). Is the repair complete? | -- | -- |