When the park lights are activated, battery positive voltage
(B+) is supplied to the foglamp switch through CKT 9 (BRN). Battery
positive voltage (B+) is supplied at all times to the switch side of the
fog lamps relay position A in the RH IP fuse block through the IP fuse block
FOG LPS fuse and CKT 1440 (ORN). With the foglamp switch in the ON
position, battery positive voltage (B+) is supplied to the coil of the fog
lamps relay position A through CKT 317 (YEL). The coil receives
ground from the lamp control module (LCM). With the fog lamps relay position
A coil energized, the coil contacts close, supplying battery positive voltage
(B+) to the fog lamps. Turning on the high beam headlights produces the
following effects:
• | The LCM removes the ground from the fog lamps relay position A. |
• | The fog lamps turn OFF. |