Generator Replacement L36
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical.
- Remove the fuel injector sight shield. Refer to
Fuel Injector Sight Shield Replacement
in Engine Mechanical.
- Remove the generator brace.
- Remove the output terminal nut.
- Disconnect the electrical connector.
- Remove the generator mounting bolts.
- Remove the generator.
Installation Procedure
- Position the generator on the engine.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator mounting bolts
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Connect the electrical connector.
- Install the output terminal nut.
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Install the generator brace and fasteners.
Tighten
• | Tighten the nut to 50 N·m (37 lb ft). |
• | Tighten the bolt to 25 N·m (18 lb ft). |
- Install the fuel injector sight shield. Refer to
Fuel Injector Sight Shield Replacement
in Engine Mechanical.
- Install the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Generator Replacement L67
Removal Procedure
- Disconnect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical.
- Remove the fuel injector sight shield. Refer to
Fuel Injector Sight Shield Replacement
in Engine
Mechanical.
- Remove the generator brace.
- Remove the output terminal nut.
- Disconnect the electrical connector.
- Remove the generator mounting
bolts.
- Remove the generator.
Installation Procedure
- Position the generator
on the engine.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator
mounting bolts
Tighten
Tighten the bolts to 50 N·m (37 lb ft).
- Connect the electrical connector.
- Install the output terminal nut.
Tighten
Tighten the nut to 20 N·m (15 lb ft).
- Install the generator
brace and fasteners.
Tighten
• | Tighten the nut to 50 N·m (37 lb ft). |
• | Tighten the bolt to 30 N·m (22 lb ft). |
- Install the fuel injector sight shield. Refer to
Fuel Injector Sight Shield Replacement
in Engine
Mechanical.
- Install the drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.