Step | Action | Value(s) | Yes | No | ||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor and/or the air delivery system. No loss of battery or ground is occurring in the blower motor circuit. The blower control module and the blower motor are not exhibiting any intermittent internal shorts. For electrical diagnosis of the blower motor circuit, refer to:
| ||||||||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check in HVAC Systems - Manual or Diagnostic System Check in HVAC Systems - Automatic | ||||||||||||||||||
2 |
Is a scrape or pop noise evident when selecting modes or temperature settings (moving a mode or temperature valve)? | -- | Go to Step 8 | Go to Step 3 | ||||||||||||||||||
3 | Is a tick/click, chirping, groaning or scraping noise present -- constantly but decreases as blower motor speed is decreased, or only at start-up/intermttent -- in all modes? | -- | Go to Step 6 | Go to Step 4 | ||||||||||||||||||
4 | Is an air rush/whistle noise evident at all blower speeds? | -- | Go to Step 9 | Go to Step 5 | ||||||||||||||||||
5 | Is the complaint of an air rush/whistle noise only while the vehicle is moving? | -- | Go to Step 12 | Go to Step 9 | ||||||||||||||||||
6 |
Did you find and correct the condition? | -- | System OK | Go to Step 7 | ||||||||||||||||||
7 |
Important: Inspect the blower motor impeller and cavity area (for any foreign material) through the access hole under the passenger compartment air filter before removing the blower motor.
Did you complete the repair? | -- | Go to Step 13 | -- | ||||||||||||||||||
8 |
Did you complete the repair? | -- | Go to Step 13 | -- | ||||||||||||||||||
9 |
Did you find and correct the condition? | -- | System OK | Go to Step 10 | ||||||||||||||||||
10 |
Important: Inspect the blower motor impeller and cavity area (for any foreign material) through the access hole under the passenger compartment air filter before removing the blower motor.
Is the noise still present? | -- | Go to Step 11 | -- | ||||||||||||||||||
11 | The most likely cause of the noise is coming from either a misaligned duct in the instrument panel or within the HVAC module door valve/seals.
Did you complete the repair? | -- | Go to Step 13 | -- | ||||||||||||||||||
12 |
Did you complete the repair? | -- | Go to Step 13 | -- | ||||||||||||||||||
13 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |