When you first turn ON the ignition, the inflatable restraint sensing and diagnostic module (SDM) performs tests to diagnose critical malfunctions within itself. Then the SDM performs the following continuous diagnostic tests on the deployment loops:
• | Deployment loop voltage out of range test |
• | Deployment loop resistance measurement test |
If the voltage out of range test detects a short to voltage condition, the resistance measurement test for that deployment loop will not be performed.
• | Ignition 1 voltage is within the normal operating voltage range. |
• | Driver frontal deployment loop is not open. |
• | Driver frontal deployment loop is not shorted to voltage. |
• | Driver frontal deployment loop is not shorted to ground. |
Driver frontal deployment loop resistance is less than 1.3 ohms for 500 milliseconds.
The SDM commands ON the AIR BAG warning lamp via Class 2 serial data.
• | The resistance of the driver frontal deployment loop is at least 1.3 ohms or more for 500 milliseconds. |
• | You can issue a CLEAR CODES command |
• | A history DTC will clear once 255 malfunction free ignition cycles have occurred. |
The following can cause an intermittent condition:
• | A short between the driver frontal high and the driver frontal low circuits. |
• | A malfunctioning shorting bar on the inflatable restraint steering wheel module 2-way connector. |
• | A malfunctioning shorting bar on the inflatable restraint steering wheel module coil 2-way connector. |
If any of the above conditions are found, refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems.
The number(s) below refer to the step number(s) on the diagnostic table.
This step checks the in-line connector below the steering wheel restraint module coil.
This step test for the proper operation of inflatable restraint steering wheel module coil and/or inflatable restraint steering wheel inflator module.
This step determines if there is a short between driver frontal high and driver frontal low circuits, or if there is a malfunctioning SDM.
Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Diagnostic System Check? | -- | ||||||||
Does connector exhibits any signs of corrosion, terminal damaged, or poor connections? | -- | |||||||||
3 |
Did you complete the replacement? | -- | -- | |||||||
4 |
Does the scan tool indicate that this DTC is current? | -- | Go to Diagnostic Aids | |||||||
5 |
Does the scan tool indicate that this DTC is current? | -- | ||||||||
Does the scan tool indicate that this DTC is current? | -- | |||||||||
7 |
Did you complete the replacement? | -- | -- | |||||||
8 |
Did you complete the replacement? | -- | -- | |||||||
Does the resistance measure less than the specified value? | OL | |||||||||
10 | Locate and repair a short between the driver frontal high and the driver frontal low deployment circuits of the SDM wiring harness connector. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- | |||||||
11 | Replace the SDM. Refer to Inflatable Restraint Sensing and Diagnostic Module Replacement . Did you complete the replacement? | -- | -- | |||||||
12 |
Did you complete the action? | -- | -- |