Dash Integration Module (DIM)
Important: The Air Bag Indicator light may remain ON after the DIM module
is replaced and during the programming procedure for the DIM until after the
procedure is completed and the ignition key is cycled OFF and ON .
• | Before replacement record the personalization settings to transfer
to the new module (if they are available). |
• | After replacement of the DIM perform the following procedure. |
• | To reprogram the DIM perform the following procedure. |
- Using a scan tool preform the New VIN Procedure.
- Perform the Setup SDM Serial Number in DIM Procedure.
- Using the scan tool, set the Point of Sale in the DIM module to
the correct country.
- Using the scan tool, configure RPO option configuration.
- Perform the vehicle personalization to reset the owner's desired
personalization settings. Refer to Instrument Cluster, Gauges and Console.
Procedure to Set Up A New DIM Module
- Connect a scan tool to the data link connector (DLC).
- Turn ON the ignition, with the engine OFF.
- Under the DIM Main Menu, select Special Functions. Under the Special
Functions menu, one of the choices is New VIN.
- The user selects one of the following:
• | New VIN, (to continue with the procedure). |
• | Exit, to go back to Special Functions menu. |
- After the user chooses New VIN, follow the scan tool on screen
instructions to edit VIN:
• | Press Save to save VIN information. |
• | Press Done to go back to Special Functions menu. |
- Under the Special Functions menu, one of the choices is Setup
SDM Serial Number in DIM.
- The user selects one of the following:
• | Setup SDM Serial Number in DIM, (to continue with the procedure). |
• | Exit, to go back to Special Functions menu. |
- After the user chooses Setup SDM Serial Number in DIM, the scan
tool displays a screen as follows:
• | Do you want to set up a Dash Integration Module? |
• | Press Yes to set up module. |
- Choose Yes or No
• | If the user selects No, the scan tool display returns to the DIM
Special Function Menu. |
• | If the user selects Yes, the scan tool displays Initializing New
Module. |
- Once complete, the scan tool displays Module Initialized.
- To complete the procedure, select the following:
- EXIT: Go to Special Functions Menu
- Under the Special Functions menu, one of the choices is Set Options.
- The user selects one of the following:
• | Set Options, (to continue with the procedure). |
• | Exit, to go back to Special Functions menu. |
- Under the Set Options menu, The user selects one of the following:
• | Point of Sale, (to continue with the procedure) follow the scan
tool on screen instructions to Select the Point of Sale. |
• | Miscellaneous Options #1, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Miscellaneous Options #2, should be turned ON. |
• | Universal Theft Deterrent, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Automatic/Manual HVAC Options, (to continue with the procedure)
follow the scan tool on screen instructions to Select the RPO option configuration. |
• | Magna Steer Option, (to continue with the procedure) follow the
scan tool on screen instructions to Select the RPO option configuration. |
• | Personalization Option, (to continue with the procedure) follow
the scan tool on screen instructions to Select the RPO option configuration. |
• | Exit, to go back to Special Functions menu. |
- Perform the vehicle personalization to reset the owner's desired
personalization settings. Refer to Instrument Cluster, Gauges and Console.
- Cycle the ignition key OFF and ON.
Instrument Panel Module (IPM)
Refer to
Instrument Panel Module Recalibration
in HVAC.
Rear Integration Module (RIM)
Before replacement record the personalization settings to transfer to
the new module (if they are available).
After replacement of the Rear Integration Module, perform the following
procedure.
- Recalibration of the automatic level control.
- Perform the vehicle personalization to reset the owner's desired
personalization settings.
Procedure to Set Up A New RIM Module
- Connect a scan tool to the Data Link Connector (DLC).
- Turn ON the ignition, with the engine OFF.
- Under the Chassis Main Menu, select Rear Integration Module.
- Under the Rear Integration Module Main Menu, select Recalibration.
- Follow the scan tool on screen instructions to recalibrate the
automatic level control.
- Perform the vehicle personalization to reset the owner's desired
personalization settings. Refer to Instrument Cluster, Gauges and Console.