Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the entire Cigar Lighter/Auxiliary Outlets System Check performed? | -- | Go to Step 2 | |
2 | Did the cigar lighters operate properly? | -- | Go to Step 3 | |
3 |
Does the test lamp illuminate? | -- | Go to Step 4 | Go to Step 7 |
4 | Connect a test lamp between the auxiliary power outlet load circuit and the auxiliary power outlet ground circuit. Does the test lamp illuminate? | -- | Go to Step 5 | Go to Step 8 |
5 | Inspect for power connections at the auxiliary power outlet. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs Did you find and correct the condition? | -- | Go to Step 9 | Go to Step 6 |
6 | Replace the auxiliary power outlet. Refer to Auxiliary Power Outlet Replacement. Did you complete the replacement? | -- | Go to Step 9 | -- |
7 | Repair the open or high resistance in the auxiliary power outlet load circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | -- | Go to Step 9 | -- |
8 | Repair the open or high resistance in the auxiliary power outlet ground circuit. Refer to Circuit Testing and Wiring Repairs . Did you complete the repair? | -- | Go to Step 9 | -- |
9 | Operate the system in order to verify the repair. Did you find and correct the condition? | -- | System OK | Go to Step 2 |