Removal Procedure
- Remove the left sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gages and Console.
- Remove the fastener (2)
from the Instrument Panel Module (IPM).
- Rotate the IPM up and out of the IP retainer.
- Disconnect the electrical connectors from the IPM (1).
Installation Procedure
- Connect the electrical
connectors to the IPM (1).
- Install the IPM (1) to the IP retainer by inserting the top tab
of the module into the slot on the IP retainer and rotating down.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the fastener.
Tighten
Tighten the fastener to 2 N·m (18 lb in).
- Install the left sound insulator. Refer to
Instrument Panel Insulator Panel Replacement - Left Side
in Instrument Panel,
Gages and Console.