Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor. | |||||||||
1 | Were you sent here from Symptoms or another diagnostic table? | Go to Step 2 | Go to Symptoms - HVAC Systems - Manual or Symptoms - HVAC Systems - Automatic | ||||||
2 | Inspect the air inlet grille for debris. Is debris present? | Go to Step 8 | Go to Step 3 | ||||||
3 |
Did you hear a noise during the blower operation? | Go to Step 4 | Go to Step 11 | ||||||
4 | Inspect for excessive vibration at each blower motor speed by feeling the blower case. Is excess vibration present? | Go to Step 6 | Go to Step 5 | ||||||
5 | Listen to the blower motor at each blower speed. Is the blower motor making a squeaking or chirping noise? | Go to Step 9 | Go to Step 11 | ||||||
6 |
Important: Inspect the blower motor impeller cavity through the access hole in the air inlet grille. Examine the blower motor cavity, blower motor and blower motor impeller for deposits of foreign material. Did you find foreign material? | Go to Step 8 | Go to Step 7 | ||||||
7 |
Did you find any of these conditions? | Go to Step 9 | Go to Step 10 | ||||||
8 | Remove the foreign material. Is the action complete? | Go to Step 11 | -- | ||||||
9 | Replace the blower motor. Refer to Blower Motor Replacement . Is the repair complete? | Go to Step 11 | -- | ||||||
10 | Install the blower motor. Refer to Blower Motor Replacement . Is the action complete? | Go to Step 11 | -- | ||||||
11 | Operate the system in order to verify the repair. Did you find and correct the condition? | System OK | Go to Step 2 |