Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Improper control response, set temperature requires frequent adjustment or changes by itself. | ||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||
2 |
Does the scan tool display any DTCs? | -- | Go to Step 3 | |||||||||
3 | Inspect for a poor battery condition. Refer to Battery Inspection/Test in Engine Electrical. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 4 | ||||||||
4 | Visually inspect for a stuck of intermittent sticking switch on the HVAC control module, Trim plate fit. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 5 | ||||||||
5 | Verify that the customer is using the correct key to enable personalization and is not inadvertently activating the right air temperature switch on the HVAC control module. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 6 | ||||||||
6 |
Does the scan tool indicate that the Right and Left Solar Sensor data parameters are more than the specified value? | 224 Counts | Go to Step 7 | Go to Step 17 | ||||||||
7 |
Do the counts change similarly and correspond to the proper side of the sunload sensor assembly? | -- | Go to Step 8 | Go to Step 17 | ||||||||
8 |
Does the paper stay in place? | -- | Go to Step 9 | Go to Step 16 | ||||||||
9 |
Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 10 | ||||||||
10 | Inspect for poor connections at the following air temperature sensor harness connectors:
Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 11 | ||||||||
11 | Test the resistance of the following air temperature sensors:
Refer to Sensor Resistance Table . Do the resistances measure near the Sensor Resistance Table values? | -- | Go to Step 12 | Go to Step 21 | ||||||||
12 | Inspect for poor connections at the harness connector of the outside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 13 | ||||||||
13 | Test the outside air temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table value? | -- | Go to Step 14 | Go to Step 19 | ||||||||
14 | Inspect for poor connections at the harness connector of the inside air temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 15 | ||||||||
15 | Test the inside air temperature sensor resistance. Refer to Sensor Resistance Table . Does the resistance measure near the Sensor Resistance Table value? | -- | System OK | Go to Step 20 | ||||||||
16 | Inspect for a blocked or disconnected aspiration hose. Did you find and correct the condition? | -- | Go to Step 22 | -- | ||||||||
17 | Inspect for poor connections at the harness connector of the sunload sensor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 22 | Go to Step 18 | ||||||||
18 | Replace the sunload sensor assembly. Refer to Sunload and Twilight Sentinel Sensor Replacement in Instrument Panel, Gages, and Console. Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||
19 | Replace the ambient air temperature sensor. Refer to Ambient Air Temperature Sensor Replacement . Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||
20 | Replace the inside air temperature sensor. Refer to Inside Air Temperature Sensor Replacement . Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||
21 | Replace the suspect air temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 22 | -- | ||||||||
22 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 3 |