- Use a small screwdriver in order to
disconnect the electrical connectors from the following parts:
• | 1-2 shift solenoid valve (909) |
• | 2-3 shift solenoid valve (910) |
• | Internal mode switch (IMS) (942) |
- Remove the 3, 10 mm
bolts (534) from the channel plate side.
- Remove the 6, 10 mm bolts (534, 951, 952, 954)
from the accumulator housing.
Important: There are 4 checkballs (65) and a spring (971) under
the accumulator housing (944).
- Remove the accumulator housing (944) from the channel plate.
- Remove the 4 checkballs (65)
and the spring (971) from the channel plate.
- In order to disconnect the manual valve
and link assembly (916) from the internal mode switch (IMS) (942),
rotate the manual valve and link assembly (916) toward the IMS (942).
- Turn the manual valve link 90 degrees
and rotate the manual valve and link assembly (916) away from the
IMS (942).
- Remove the 3, 8 mm bolts (939)
from the internal mode switch (IMS) (942).
- Remove the IMS (942).
- Remove the 15, 10 mm bolts (938,
940, 941) from the lower control valve body.
- Remove the solenoid valve fluid filter retainer (981).
- Remove the lower control valve assembly (903) from the
channel plate.
- Remove the 4 checkballs (65).
- Remove the spacer plate and gasket assembly (935) from
the channel plate (900).