Caution: Refer to Brake Fluid Irritant Caution in the Preface section.
Notice: Refer to Brake Fluid Effects on Paint and Electrical Components Notice in the Preface section.
Perform a manual or pressure bleeding procedure. Refer to Hydraulic Brake System Bleeding in Hydraulic Brakes. If the desired brake pedal height results are not achieved, perform the automated bleed procedure below.
The procedure cycles the system valves and runs the pump in order to purge the air from the secondary circuits normally closed off during normal base brake operation and bleeding. The automated bleed procedure is recommended when air ingestion is suspected in the secondary circuits, or when the brake pressure modulator valve (BPMV) has been replaced.
Notice: The Auto Bleed Procedure may be terminated at any time during the process by pressing the EXIT button. No further Scan Tool prompts pertaining to the Auto Bleed procedure will be given. After exiting the bleed procedure, relieve bleed pressure and disconnect bleed equipment per manufacturers instructions. Failure to properly relieve pressure may result in spilled brake fluid causing damage to components and painted surfaces.
• | If a DTC is detected, refer to Diagnostic Trouble Code (DTC) List - Vehicle in Vehicle Control Systems and diagnose the appropriate DTC. |
• | If the brake pedal feels spongy, perform the conventional brake bleed procedure again. Refer to Hydraulic Brake System Bleeding in Hydraulic Brakes. |