5.1. | Install a vacuum pump to the nipple side of the check valve, AIR pump side. |
5.2. | Pump the vacuum pump to 10 inches Hg. and observe the gauge. |
5.3. | If the vacuum bleeds down to zero within 5 seconds, replace the check valve. |
Tighten
Tighten the Check valve to the AIR pipe 23 N·m (17 lb ft).
4.1. | Install a vacuum pump to the nipple side of the check valve, AIR pump side. |
4.2. | Pump the vacuum pump to 10 inches Hg. and observe the gauge. |
4.3. | If the vacuum bleeds down to zero within 5 seconds, replace the check valve. |
Tighten
Tighten the Check valve to 23 N·m (17 lb ft).
Important: The new cross under pipe must be cut similarly to the old pipe before installation.