Step | Action | Value(s) | Yes | No | ||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important: Insufficient heating may be caused by the following conditions:
| ||||||||||||||
1 | Inspect for the following conditions:
Are any of these conditions present? Repair as necessary. Is the repair complete? | -- | System OK | |||||||||||
2 |
Is there high air flow? | -- | ||||||||||||
3 | Inspect the blower speed for airflow change. Does the speed of the airflow change? | -- | System OK | |||||||||||
4 |
Is the heater output temperature correct? | -- | ||||||||||||
5 |
| -- | -- | -- | ||||||||||
6 |
Is there a valve slam? | -- | ||||||||||||
7 |
Is there valve slam? | -- | ||||||||||||
8 | Replace the temperature control cable. Refer to Temperature Control Cable Replacement . Is the repair complete? | -- | System OK | -- | ||||||||||
9 |
Is the inlet hose hotter than the outlet hose? | -- | ||||||||||||
10 |
Is the inlet hose hotter than the outlet hose? | -- | ||||||||||||
11 | Repeat the test. Do the symptoms still exist? | -- | -- | -- | ||||||||||
12 | Replace the heater core. Is the repair complete? | -- | System OK | -- | ||||||||||
13 | Inspect the thermostat for proper installation and seating. Are the installation and seating correct? | -- | ||||||||||||
14 | Replace the thermostat. Refer to Engine Coolant Thermostat Replacement in Engine Cooling. Is the repair complete? | -- | System OK | -- | ||||||||||
15 |
| -- | -- | -- | ||||||||||
16 | Run the Functional Check . Is the condition corrected? | -- | System OK | |||||||||||
17 | Inspect the airflow from the defroster and vent outlets. Is there high airflow from the defroster or vent outlets? | -- | ||||||||||||
18 |
Is the repair complete? | -- | System OK | -- | ||||||||||
19 |
Is the defroster airflow correct? | -- | ||||||||||||
20 | Inspect the floor air outlet for obstructions. | -- | -- | -- | ||||||||||
21 | Inspect the blower speeds for airflow change. Does the speed of the airflow change? | -- | ||||||||||||
22 | Inspect for airflow obstructions at blower inlet and plenum. Are there obstructions at the blower inlet and the plenum? | -- | -- | |||||||||||
23 |
Does the speed of the airflow change? | -- | ||||||||||||
24 | Inspect for airflow obstruction between the blower and the system outlets. Is there an obstruction? | -- | ||||||||||||
25 |
Are the repairs complete? | -- | System OK | -- | ||||||||||
26 |
Are the repairs complete? | -- | System OK | -- |