Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the entire HVAC Blower Controls System Check performed? | -- | Go to Step 2 | |
2 |
Does the test light illuminate? | -- | Go to Step 3 | Go to Step 4 |
3 | Replace the blower resistor. Refer to Blower Motor Resistor Replacement Is the repair complete? | -- | Go to Step 7 | -- |
4 | Connect a test light at the HVAC control selector switch connector C1 terminal A and ground. Does the test light illuminate? | -- | Go to Step 5 | Go to Step 6 |
5 | Repair a poor connection or open in circuit 60. Is the repair complete? | -- | Go to Step 7 | -- |
6 | Replace the HVAC control selector switch. Refer to Control Assembly Replacement Is the repair complete? | -- | Go to Step 7 | -- |
7 |
Have all the repairs been made? | -- | -- |