Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 |
Does the test lamp light? | -- | Go to Step 2 | Go to Step 8 |
2 | Connect a test lamp from UH electrical center 1 terminal E8 to ground. Does the test lamp light? | -- | Go to Step 3 | Go to Step 9 |
3 |
Does the test lamp light? | -- | Go to Step 4 | Go to Step 10 |
4 | Connect a fused jumper between UH electrical center 1 terminals E6 and F6. Does the horn sound? | -- | Go to Step 15 | Go to Step 5 |
5 |
Does the test lamp light? | -- | Go to Step 6 | Go to Step 13 |
6 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 14 |
7 |
Is the repair complete? | -- | System OK | -- |
8 | Repair the open or the poor connection in CKT 1140 between UH electrical center 1 terminal E6 and Horn fuse. Is the repair complete? | -- | System OK | -- |
9 | Repair the open or poor connection in CKT 1140 between UH electrical center 1 terminal E8 and S168. Is the repair complete? | -- | System OK | -- |
10 |
Does the test lamp light? | -- | Go to Step 11 | Go to Step 12 |
11 | Repair the open or poor connection in CKT 28 between connector C216 and UH electrical center 1. Is the repair complete? | -- | System OK | -- |
12 |
Is the repair complete? | -- | System OK | -- |
13 | Repair the open in CKT 250 between horn connector terminal A and S112. Is the repair complete? | -- | System OK | -- |
14 | Repair the open in CKT 29 between horn connector terminal B and UH electrical center 1 terminal F6. Is the repair complete? | -- | System OK | -- |
15 |
Is the repair complete? | -- | System OK | -- |