Step
| Action
| Value(s)
| Yes
| No
|
1
|
- Disconnect the body control module (BCM) connector C2
and connector C3.
- Connect a 15A fused jumper from BCM connector C2 terminal B
to connector C3 terminal C4.
Is the fasten seat belt indicator on?
| --
|
Go to Step 2
|
Go to Step
3
|
2
|
- Test for a poor connection at the BCM connector C3 terminal C4.
- If the connection is OK, Replace the BCM. Refer to
Body Control Module Replacement
.
Is the repair complete?
| --
| System OK
| --
|
3
|
- Leave the 15A fused jumper connected.
- Connect a test lamp from instrument cluster connector terminal A13
to ground.
Does the test lamp light?
| --
|
Go to Step
5
|
Go to Step 4
|
4
| Repair the open in circuit 237 between the BCM and the instrument
cluster.
Is the repair complete?
| --
| System OK
| --
|
5
|
- Test for an open in circuit 650 between the instrument
cluster and S216.
- Test for a poor connection at the instrument cluster connector.
- If circuit 650 and the connections are OK, replace the
instrument cluster. Refer to
Instrument Cluster Replacement
.
Is the repair complete?
| --
| System OK
| --
|