Removal Procedure
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect
the negative battery cable.
- Relieve the fuel system pressure. Refer to the
Fuel Pressure Relief
.
- Clean all the engine compartment connecting fuel pipe connections
and the surrounding areas before disconnecting in order to avoid possible
contamination of the fuel system.
- Disconnect the engine compartment fuel feed pipe (2) at
the fuel rail (1). Refer to
Metal Collar Quick Connect Fitting Service
.
- Disconnect the engine compartment fuel feed pipe (2) at
the chassis fuel feed pipe (4). Refer to
Metal Collar Quick Connect Fitting Service
.
- Cap the fuel pipes in order to prevent possible fuel system contamination.
Installation Procedure
- Remove the caps from the
fuel pipes.
- Connect the engine compartment fuel feed pipe (2) to the
chassis fuel feed pipe (3). Refer to
Metal Collar Quick Connect Fitting Service
.
- Connect the engine compartment fuel feed pipe (2) to the
fuel rail (1). Refer to
Metal Collar Quick Connect Fitting Service
.
- Tighten the fuel filler cap.
- Connect the negative battery cable.
- Inspect for leaks.
6.1. | Turn ON the ignition for 2 seconds. |
6.2. | Turn OFF the ignition for 10 seconds. |
6.3. | Turn ON the ignition. |
6.4. | Inspect for fuel leaks. |
- Perform the Idle Learn Procedure. Refer to
Idle Learn
.