Blower Motor Resistor Assembly Replacement for Pontiac Firebird 2001
Removal Procedure
- Remove the right IP insulator.
Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in Instrument Panel, Gages and Console.
- Position the carpet away from the HVAC module assembly.
- Remove the blower resistor assembly bolt (2).
- Disconnect the blower resistor assembly electrical connector.
- Remove the blower resistor assembly (1).
Installation Procedure
- Install the blower motor
resistor assembly (1).
Notice: Refer to Fastener Notice in the Preface section.
- Connect the blower motor resistor assembly electrical connector.
- Install the blower motor resistor bolt (2).
Tighten
Tighten the bolt to 2 N·m (18 lb in).
- Reposition the carpet.
- Install the right instrument panel insulator. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
in
Instrument Panel, Gages, and Console.