Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
DEFINITION: Noise originating from the blower motor and/or the air delivery system. No loss of battery or ground is occurring in the blower motor circuit. The blower motor resistor and the blower motor are not exhibiting any intermittent internal shorts. For electrical diagnosis of the blower motor circuit, refer to Blower Motor Inoperative in HVAC Systems - Manual. | ||||||||||||||||
1 | Were you sent here from A Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Manual in HVAC Systems - Manual | ||||||||||||
2 |
Is a scrape or pop noise evident when selecting modes or temperature settings (moving a mode or temperature valve)? | -- | Go to Step 12 | Go to Step 3 | ||||||||||||
3 | Is a tick/click, chirping, groaning or scraping noise present (constantly but decreases as blower motor speed is decreased, or only at start-up/intermttent) in all modes? | -- | Go to Step 6 | Go to Step 4 | ||||||||||||
4 | Is an air rush/whistle noise evident in all modes but not all temperature settings? | -- | Go to Step 13 | Go to Step 5 | ||||||||||||
5 | Is an air rush/whistle noise evident only in defrost or lower mode? | -- | Go to Step 14 | Go to Step 15 | ||||||||||||
6 | Check for blower motor and impeller excess vibration at each blower motor speed by feeling the blower case. Is excessive vibration present? | -- | Go to Step 7 | Go to Step 9 | ||||||||||||
7 |
Refer to Blower Motor and Fan Replacement .
Does the blower motor impeller exhibit any of these abnormal conditions? | -- | Go to Step 8 | Go to Step 9 | ||||||||||||
8 |
Refer to Blower Motor and Fan Replacement . Is the action complete? | -- | Go to Step 16 | -- | ||||||||||||
9 |
Refer to Blower Motor and Fan Replacement . Was foreign material found? | -- | Go to Step 11 | Go to Step 10 | ||||||||||||
10 |
Refer to Blower Motor and Fan Replacement . Is the repair complete? | -- | Go to Step 17 | -- | ||||||||||||
11 |
Is the action complete? | -- | Go to Step 17 | -- | ||||||||||||
12 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | Go to Step 17 | -- | ||||||||||||
13 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | Go to Step 17 | -- | ||||||||||||
14 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | Go to Step 17 | -- | ||||||||||||
15 |
Refer to Instrument Panel Upper Trim Pad Replacement in Instrument Panel, Gauges and Console. Is the action complete? | -- | Go to Step 17 | -- | ||||||||||||
16 |
Is the noise still present? | -- | Go to Step 10 | Go to Diagnostic System Check - HVAC Systems - Manual in HVAC Systems - Manual | ||||||||||||
17 |
Is the noise still present? | -- | Go to Step 2 | Go to Diagnostic System Check - HVAC Systems - Manual in HVAC Systems - Manual |