Step | Action | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: Temperature can not be adjusted or heating insufficient. | |||||||||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |||||||
2 |
Does the blower motor operate at all? | Go to Step 3 | Go to Blower Motor Inoperative | ||||||
3 | Does the blower motor operate correctly for each speed position? | Go to Step 4 | Go to Blower Motor Malfunction | ||||||
4 | Inspect the cooling system for the following conditions:
Did you find and correct the condition? | Go to Step 8 | Go to Step 5 | ||||||
5 |
Does the A/C compressor operate? | Go to Step 6 | |||||||
6 | Inspect the air temperature cable for the following:
Did you find and correct the condition? | Go to Step 8 | Go to Step 7 | ||||||
7 | Inspect the air temperature door for the following conditions:
Did you find and correct the condition? | Go to Step 8 | |||||||
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |