Important:
• Any new BCM will automatically program to the resistance of the
ignition key being used at the first ignition ON cycle. This can only be done
once for the life of the module. • The BCM can only be programmed to one ignition key resistance.
All ignition key resistances must match.
A new BCM is not programmed. Before the system will function properly it must be programmed to the code that matches the customer's keys.
• | The indicator lamp lights steadily for approximately 5 seconds and then goes out. This indicates that the BCM is programmed properly. |
• | The indicator lamp flashes at a rate of one flash per second until the ignition is turned OFF. This indicates that the BCM did not program and the system should be checked for a fault. Refer to Security Indicator Always On or Flashing in Theft Deterrent. |
Important: After programming, perform the following to avoid future misdiagnosis: