Generator Replacement 3.8L Engine
Removal Procedure
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect the negative
battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the accessory drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 3.8L.
- Disconnect the generator electrical connector.
- Remove the positive cable
from the generator:
• | Slide the boot back along the cable. |
• | Remove the positive cable nut (at generator). |
• | Remove the positive cable from the stud. |
- Remove the canister purge solenoid. Refer to
Evaporative Emission Canister Purge Solenoid Valve Replacement
in
Engine Controls - 3.8L.
- Remove the generator bolts
(2, 3, 6).
- Remove the generator (1).
Installation Procedure
- Install the generator
(1).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator bolts (2, 3, 6).
Tighten
• | Tighten the generator bolt (2, 6) to 30 N·m (22 lb ft). |
• | Tighten the generator bolt (3) to 50 N·m (37 lb ft). |
- Install the canister purge solenoid. Refer to
Evaporative Emission Canister Purge Solenoid Valve Replacement
in
Engine Controls - 3.8L.
- Install the positive cable
to the generator:
• | Install the positive cable to the stud. |
• | Install the positive cable nut (at generator). |
Tighten
Tighten the positive cable nut (at generator) to 22 N·m
(16 lb ft).
• | Slide the boot over the generator stud. |
- Connect the electrical
connector to the generator.
- Install the accessory drive belt. Refer to
Drive Belt Replacement
in Engine Mechanical - 3.8L.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
Generator Replacement 5.7L Engine
Removal Procedure
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect the negative
battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.
- Remove the accessory drive belt. Refer to
Drive Belt Replacement - Accessory
in Engine Mechanical - 5.7L.
- Raise and suitably support the vehicle. Refer to
Lifting and Jacking the Vehicle
in General Information.
- Remove the positive cable from the generator:
• | Slide the boot back along the cable. |
• | Remove the positive cable nut (at generator). |
• | Remove the positive cable from the stud. |
- Remove the generator rear
bracket mounting bolt (1).
- Remove the transmission
oil cooler lines from the oil cooler clip.
- Remove the generator front mounting bolts and oil cooler clip.
- Disconnect the generator
electrical connector (3).
- Remove the generator.
Installation Procedure
- Install the generator.
- Connect the generator electrical connector (3).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the generator
front mounting bolts and oil cooler clip.
Tighten
Tighten the generator mounting bolts to 50 N·m (37 lb ft).
- Install the transmission oil cooler lines to the oil cooler clip.
- Install the generator
rear mounting bolt (1) (at generator).
Tighten
Tighten the generator rear mounting bolt (at generator) to 25 N·m
(18 lb ft).
- Install the positive cable
to the generator:
• | Install the positive cable to the stud. |
• | Install the positive cable nut (at generator). |
Tighten
Tighten the positive cable nut (at generator) to 22 N·m
(16 lb ft).
• | Slide the boot over the generator stud. |
- Lower the vehicle.
- Install the accessory drive belt. Refer to
Drive Belt Replacement - Accessory
in Engine Mechanical - 5.7L.
- Connect the negative battery cable. Refer to
Battery Negative Cable Disconnection and Connection
.