Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: HVAC Schematics DEFINITION: The blower motor operates in at least one, but not all, speed positions. | |||
1 | Did you perform the HVAC Diagnostic System Check? | Go to Step 2 | |
2 |
Does the blower motor operate at the correct speed in each speed position? | Go to Step 3 | Go to Step 4 |
3 |
Does the blower motor operate in each mode position? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 18 |
4 |
Does the test lamp illuminate in each speed position? | Go to Step 16 | Go to Step 5 |
5 | Does the test lamp illuminate in the maximum speed position? | Go to Step 10 | Go to Step 6 |
6 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 19 |
7 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 8 |
8 | Test the high blower motor control circuit of the blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 14 |
9 | Test the ground circuit of the blower motor relay for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 15 |
10 |
Does the test lamp illuminate in each speed position? | Go to Step 15 | Go to Step 11 |
11 | Test the blower motor supply voltage circuit between the blower motor resistor and blower motor relay for an open, short to ground, or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 12 |
12 |
Does the test lamp illuminate in each speed position? | Go to Step 17 | Go to Step 13 |
13 | Test the suspect blower motor control circuit of the blower motor resistor assembly for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 18 |
14 | Test the OFF blower motor control circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 18 |
15 | Inspect for poor connections at the harness connector of the blower motor relay. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 20 |
16 | Inspect for poor connections at the harness connector of the blower motor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 21 |
17 | Inspect for poor connections at the harness connector of the blower motor resistor assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 22 |
18 | Inspect for poor connections at the harness connector of the HVAC control assembly. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 24 | Go to Step 23 |
19 | Repair the battery positive voltage circuit of the blower motor relay. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 24 | -- |
20 | Replace the blower motor relay. Did you complete the replacement? | Go to Step 24 | -- |
21 | Replace the blower motor. Refer to Blower Motor Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 24 | -- |
22 | Replace the blower motor resistor assembly. Refer to Blower Motor Resistor Assembly Replacement in Heating, Ventilation and Air Conditioning. Did you complete the replacement? | Go to Step 24 | -- |
23 | Replace the HVAC control assembly. Refer to Heater and Air Conditioning Control Replacement . Did you complete the replacement? | Go to Step 24 | -- |
24 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |