Step | Action | Yes | No |
---|---|---|---|
1 | Did you perform the Door Systems Diagnostic System Check? | Go to Step 2 | |
2 |
Do both of the windows operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Is the driver window inoperative? | Go to Step 11 | Go to Step 4 |
4 | Does the passenger window operate from the driver window switch? | Go to Step 19 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 6 | Go to Step 7 |
6 |
Does the test lamp illuminate? | Go to Step 9 | Go to Step 8 |
7 | Test the power window master switch output right front up circuit for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 21 |
8 | Test the power window master switch output right front down circuit for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 21 |
9 |
Does the test lamp illuminate for both conditions? | Go to Step 22 | Go to Step 10 |
10 | Test the control circuits for an open and for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 20 |
11 | Does the passenger window operate from the driver switch for the passenger window? | Go to Step 12 | Go to Step 18 |
12 |
Does the test lamp illuminate? | Go to Step 13 | Go to Step 14 |
13 |
Does the test lamp illuminate? | Go to Step 16 | Go to Step 15 |
14 | Test the power window motor left front up circuit for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 21 |
15 | Test the power window master switch left front down circuit for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 21 |
16 |
Does the test lamp illuminate for both conditions? | Go to Step 22 | Go to Step 17 |
17 | Test the power window motor left front up circuit and the power window motor feed left front down circuit for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 23 |
18 |
Does the test lamp illuminate? | Go to Step 21 | Go to Step 24 |
19 |
Does the test lamp illuminate? | Go to Step 20 | Go to Step 25 |
20 | Inspect for intermittent and poor connections at the passenger window switch. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 26 |
21 | Inspect for intermittent and poor connections at the driver window switch. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 27 |
22 | Inspect for intermittent and poor connections at the inoperative window motor. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 28 |
23 | Inspect for intermittent and poor connections at the inoperative window control module. Refer to Testing for Intermittent Conditions and Poor Connections in Wiring Systems. Did you find and correct the condition? | Go to Step 30 | Go to Step 29 |
24 | Repair the open in the ignition voltage circuit to the driver window switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 30 | -- |
25 | Repair the open in the ignition voltage circuit to the passenger window switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | Go to Step 30 | -- |
26 | Replace the passenger window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | Go to Step 30 | -- |
27 | Replace the driver window switch. Refer to Front Side Door Window Switch Replacement . Is the repair complete? | Go to Step 30 | -- |
28 | Replace the inoperative window regulator. Refer to Door Window Regulator Replacement . Is the repair complete? | Go to Step 30 | -- |
29 | Replace the window control module. Refer to Power Window Control Module Replacement . Is the repair complete? | Go to Step 30 | -- |
30 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |