The powertrain control module (PCM) monitors the heated oxygen sensor (HO2S) activity. Within a 100 second test period, the PCM counts the number of times that the HO2S signal voltage crosses the rich-to-lean-to-rich thresholds. If the PCM determines that the HO2S did not switch enough times, DTC P1153 will be set. A lean to rich switch is determined when the HO2S voltage changes from less than 300 mV to more than 600 mV. A rich to lean switch is determined when the HO2S voltage changes from more than 600 mV to less than 300 mV.
DTCs P0101, P0102, P0103, P0107, P0108, P0112, P0113, P0117, P0118, P0121, P0122, P0123, P0125, P0128, P0201-P0206, P0300, P0410, P0440, P0442, P0443, P0446, P0449, or P1441 are not set.
• | The PCM monitors fewer than 55 lean-to-rich and rich-to-lean switches for bank 2 HO2S 1. |
• | The HO2S voltage remains between 300-600 millivolts. |
• | The conditions are present for 2 minutes after Closed Loop enable. |
• | The control module illuminates the malfunction indicator lamp (MIL) on the second consecutive ignition cycle that the diagnostic runs and fails. |
• | The control module records the operating conditions at the time the diagnostic fails. The first time the diagnostic fails, the control module stores this information in the Failure Records. If the diagnostic reports a failure on the second consecutive ignition cycle, the control module records the operating conditions at the time of the failure. The control module writes the operating conditions to the Freeze Frame and updates the Failure Records. |
• | The control module turns OFF the malfunction indicator lamp (MIL) after 3 consecutive ignition cycles that the diagnostic runs and does not fail. |
• | A current DTC, Last Test Failed, clears when the diagnostic runs and passes. |
• | A history DTC clears after 40 consecutive warm-up cycles, if no failures are reported by this or any other emission related diagnostic. |
• | Clear the MIL and the DTC with a scan tool. |
If the condition is intermittent, refer to Intermittent Conditions .
The numbers below refer to the step numbers on the diagnostic table.
When the system is operating correctly, the HO2S voltage should toggle above and below the specified values.
If the HO2S low signal circuit is shorted to ground, the HO2S voltage will be less than 400 mV when the HO2S high signal circuit is jumped to ground.
The specified value is what is measured on a correctly operating system.
The specified value is what is measured on a correctly operating system.
The new PCM must be programmed.
Step | Action | Values | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: Engine Controls Schematics | ||||||||||
1 | Did you perform the Diagnostic System Check-Engine Controls? | -- | Go to Step 2 | |||||||
Important: If any other DTCs are set, except HO2S DTCs, refer to the other DTCs first before proceeding.
Does scan tool indicate HO2S voltage varying outside the specified values? | 400-500 mV | Go to Step 3 | Go to Step 4 | |||||||
3 | Operate the vehicle within Failure Records conditions. Does the scan tool indicate this DTC failed this ignition? | -- | Go to Step 4 | Go to Intermittent Conditions | ||||||
4 | Inspect and test for the following conditions:
Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 5 | ||||||
Does the scan tool indicate HO2S voltage more than the specified value? | 400 mV | Go to Step 6 | Go to Step 10 | |||||||
Does the voltage measure near the specified value? | 4.5 V | Go to Step 7 | Go to Step 9 | |||||||
Measure the voltage on the HO2S low signal circuit on the PCM side, using a DMM that is connected to a good ground. Does the voltage measure near the specified value? | 5 V | Go to Step 11 | Go to Step 8 | |||||||
8 | Test the HO2S low signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 13 | ||||||
9 | Test the HO2S high signal circuit for an open or high resistance. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 13 | ||||||
10 | Test the HO2S low signal circuit for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 14 | ||||||
11 | Inspect for poor connections at the HO2S. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 12 | ||||||
12 |
Important: Determine the cause of contamination before replacing the sensor.
Notice: Contamination of the oxygen sensor can result from the use of an inappropriate RTV sealant (not oxygen sensor safe) or excessive engine coolant or oil consumption. Remove the HO2S and visually inspect the portion of the sensor exposed to the exhaust stream in order to check for contamination. If contaminated, the portion of the sensor exposed to the exhaust stream will have a white powdery coating. Silicon contamination causes a high but false HO2S signal voltage (rich exhaust indication). The control module will then reduce the amount of fuel delivered to the engine, causing a severe driveability problem. Eliminate the source of contamination before replacing the oxygen sensor.
Did you complete the replacement? | -- | Go to Step 15 | -- | ||||||
13 | Inspect for poor connections at the PCM. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 15 | Go to Step 14 | ||||||
Replace the PCM. Refer to Powertrain Control Module Replacement . Did you complete the replacement? | -- | Go to Step 15 | -- | |||||||
15 |
Does the DTC run and pass? | -- | Go to Step 16 | Go to Step 2 | ||||||
16 | With a scan tool, observe the stored information, Capture Info. Does the scan tool display any DTCs that you have not diagnosed? | -- | System OK |