Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 |
Is there airflow coming out of any of the outlets? | -- | Go to Step 7 | Go to Step 2 | ||||||||
2 |
Is air blowing through the vent outlets at ambient temperature and is no air blowing through the heater, the defroster, and the side window defroster outlets? | -- | Go to Step 3 | Go to Step 7 | ||||||||
3 |
Is hot air blowing through the heater outlet at the blower hi speed, is minimum hot air blowing through the defroster, and the side window defroster outlets, and is no air blowing through the vent outlets? | -- | Go to Step 4 | Go to Step 7 | ||||||||
4 |
Is hot air blowing through the defroster outlet at blower hi speed, is minimum hot air blowing through the heater and the side window defroster outlets, and is no air blowing through the vent outlets? | -- | Go to Step 5 | Go to Step 7 | ||||||||
5 |
Is the door travel and effort OK? | -- | Go to Step 6 | Go to Step 8 | ||||||||
6 | Inspect the control cable(s) travel by moving the corresponding control at the heater control unit. Is the control cable travel OK? | -- | Go to Step 9 | Go to Step 10 | ||||||||
7 | Repair the affected control cable(s) as necessary. Refer to the following: Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
8 | Repair the affected door at the heater case. Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
9 | Reinstall the control cable(s). Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
10 | Repair the control cable(s) attachment at the heater control unit. Is the repair complete? | -- | Go to Step 11 | -- | ||||||||
11 | Perform the functional test. Refer to Function Test . Is the repair complete? | -- | -- |