Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Audible Warnings System Check? | -- | Go to Step 2 | |
2 |
Does the test lamp light? | -- | Go to Step 3 | Go to Step 4 |
3 | Connect a J 35616-200 from the audio alarm module connector cavity 5 to ground. Does the test lamp light? | -- | Go to Step 5 | Go to Step 6 |
4 | Use a J 35616-200 in order to backprobe the LH door jamb switch connector cavity to B+. Does the test lamp light? | -- | Go to Step 9 | Go to Step 10 |
5 |
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 |
6 | Replace the audio alarm module. Is the repair complete? | -- | -- | |
7 | Test for a short to B+ using a J 39200 in the BLK/WHT wire between the junction block connector C4 cavity 3, the instrument panel cluster assembly connector C3 cavity 11and audio alarm module connector cavity 5. Is there a short to B+ in the BLK/WHT wire? | -- | Go to Step 11 | Go to Step 12 |
8 | Replace the junction block. Is the repair complete? | -- | -- | |
9 | Repair the open in the BLK/BLU wire between the audio alarm module and the LH door jamb switch. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
10 |
Is the repair complete? | -- | -- | |
11 | Repair the short to B+ in the BLK/WHT wire. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | -- | |
12 | Replace the Instrument cluster printed circuit. Refer to Printed Instrument Cluster Circuit Replacement . Is the repair complete? | -- | -- |