Engine Coolant Thermostat Housing Replacement for Pontiac Firefly (Canada) 2000
Removal Procedure
Caution: Unless directed otherwise, the ignition and start switch must be in the OFF or LOCK position, and all electrical loads must be OFF before servicing
any electrical component. Disconnect the negative battery cable to prevent an electrical spark should a tool or equipment come in contact with an exposed electrical terminal. Failure to follow these precautions may result in personal injury and/or damage to
the vehicle or its components.
- Disconnect
the negative battery cable.
- Drain the engine cooling
system. Refer to
Cooling System Draining and Filling
in Engine Cooling.
- Release the hose clamp
in order to remove the upper radiator hose at the thermostat housing cap.
- Remove the two retaining bolts in order to remove the water outlet
(3) from the housing (1).
- Remove the thermostat (2) and the O-ring from the thermostat housing.
- Remove the Engine Coolant
Temperature (ECT) sensor (3).
- Remove the two bolts in order to remove the thermostat housing
and gasket from the cylinder head.
Installation Procedure
- Connect the thermostat
housing and the new gasket to the cylinder head (4).
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Secure the housing
with two bolts.
Tighten
Tighten the thermostat housing bolts to 27 N·m (20 lb ft).
- Install the Engine Coolant
Temperature (ECT) sensor (3).
- Install the thermostat and a new gasket to the thermostat housing
(2).
- Install the water outlet to the housing.
- Secure the water outlet with two retaining bolts.
Tighten
Tighten the water outlet retaining bolts to 20 N·m (15 lb ft).
- Install the upper radiator hose to the thermostat housing cap.
- Secure the hose with a hose clamp.
- Refill the engine cooling system. Refer to
Cooling System Draining and Filling
in Engine Cooling.
- Connect the negative battery cable.